Engineering & CAD
Engineering datasets and tasks for AI.
Starting with ship design and CAD. Discuss a scoped dataset of drawings, models and completed records, or commission tasks with reference solutions and verifiers.
Why engineering needs its own data
A design can look right and still fail.
On the co-authored design tasks in PLE, Google’s engineering benchmark, the best agent’s deliverables meet 91% of constraints on average. Only 41.3% meet every hard constraint.
Shape is not function.
Two parts can match almost everywhere and differ on the one bore, slot or wall that decides whether they assemble, seal or carry the load.
Intent lives in the history.
Why a plate thickened or a duct moved sits in a class comment, an RFI or a change order, not in the final file.
Every drawing is also a number.
A tank holds a volume, a floor a quantity of concrete, a part a price. An agent that edits the drawing without recomputing them has done half the job.
Source: Physical-Engineering’s Last Exam, Google Cloud AI Research, October 2026.
Domains
Choose the engineering domain.
Ship design and naval architecture
Small tankers, workboats and offshore vessels: general arrangement, lines plan, tank capacity, intact stability and loading conditions, structure and scantlings, and class approval comments.
Construction and building design
Architectural, structural and MEP drawing sets, BIM and IFC models, revisions, RFIs and clash reports, and quantity take-offs.
Mechanical parts and assemblies
Fixtures, brackets, plates and turned parts: parametric models with feature history, drawings with tolerances and fits, bills of materials and revisions.
Energy and utilities engineering
Solar plants and water works: layouts, single-line diagrams, P&IDs, bills of materials, tenders, and commissioning and maintenance records.
Industrial and product design
Product surfaces, assemblies and design reviews, with design for manufacture and assembly.
Agent access
What can the agent use?
The same task in three access modes separates an agent that cannot read the drawing from one that cannot do the engineering.
Files
Native 3D models and drawings, read through a CAD kernel in code.
Pixels
Drawing sheets and rendered views only, as an engineer reads a PDF.
Tools
CAD operations as tool calls: rotate, section, measure, query.
What a set contains
The model, the drawings, and why they changed.
What a set can include in each domain.
| Artefact | What it holds | Delivered as |
|---|---|---|
| General arrangement and profile | Spaces, tanks and equipment, deck by deck | PDF and DXF |
| Lines plan and offsets | Hull form: stations, waterlines, buttocks; the offset table | DXF, CSV |
| Capacity plan and tank tables | Volume, centre of gravity and free-surface moment per tank, by sounding | PDF, CSV |
| Stability booklet | Hydrostatics, cross curves, loading conditions, righting-lever curves and criteria | PDF, CSV |
| Structural drawings | Midship section, scantlings, shell expansion, details | PDF and DXF |
| 3D model, where one exists | Hull form; structure and outfitting where modelled | STEP, IFC or the native export |
| Revisions and class comments | What changed, why, and the class society comment it answers | JSON, with the PDFs |
| Artefact | What it holds | Delivered as |
|---|---|---|
| Drawing sets | Architectural, structural and MEP sheets: plans, sections, details, title blocks and revision clouds | PDF, and DWG or DXF |
| BIM model | Elements by discipline, with type, level, material and properties | IFC or the native export |
| Schedules and bill of quantities | Door, window and finish schedules; measured quantities by item | CSV, with the PDFs |
| Revisions and RFIs | Each revision, the RFI or instruction that prompted it, and the answer | JSON, with the PDFs |
| Clash reports | Clashes between disciplines, their status and how each was resolved | BCF or CSV |
| Specifications | Materials, workmanship and the standards each section cites | PDF and text |
| Artefact | What it holds | Delivered as |
|---|---|---|
| Parametric part models | Feature tree, sketches, constraints and named parameters | The native file where licensed, or a CadQuery script for generated parts, plus STEP |
| Drawings | Views, dimensions, tolerances and fits, the title block and revision table | PDF and DXF |
| Revision history | Each change order: what changed, why, and the message that asked for it | JSON, with the emails |
| Bills of materials | Parts, quantities and materials, with supplier part numbers removed | CSV |
| Manufacturing context | Routing, machine, cycle time and the quote the part was priced on | JSON or SQLite |
| Inspection | Measured dimensions against the drawing, pass or fail, and rework | CSV |
| Artefact | What it holds | Delivered as |
|---|---|---|
| Layouts | Solar array and plant layouts; pipework and pumping stations | PDF and DXF |
| Single-line diagrams | Strings, inverters, protection and cable ratings | PDF and DXF |
| P&IDs | Lines, pumps, valves and instruments, with the equipment list | PDF and DXF, CSV |
| Bills of materials and quotations | Equipment and quantities, with the quotation or tender | CSV, with the PDFs |
| Commissioning and maintenance | Test sheets, punch lists and maintenance logs against the design | CSV, with the PDFs |
Task families
Inspect the jobs in your domain.
Ship design and naval architecture
| Task | The agent must | Verified by |
|---|---|---|
| Tank capacity and trim | Compute volumes, centres and trim for a loading condition from the tank plan and hydrostatics | Recomputation, with a tolerance per quantity |
| Intact stability check | Build the righting-lever curve and check it against the intact stability criteria | Recomputed curve; each criterion pass or fail |
| Drawing consistency | Find where the general arrangement, tank plan and structure disagree | Set match against known conflicts |
| Answer a class comment | Revise a drawing or calculation so it meets the comment | Deliverable checks on the revised values |
Construction and building design
| Task | The agent must | Verified by |
|---|---|---|
| Quantity take-off | Measure concrete, steel, areas and counts from the drawings or the BIM model | Recomputation from the model, with a tolerance per item |
| Clash detection | Find where structure, services and architecture collide | Set match against known clashes |
| Drawing to BIM consistency | Find where the drawing set and the model disagree | Set match against known discrepancies |
| Code compliance | Check egress widths, or beam spans against their loads, under the applicable rule | Rule recomputation; each clause pass or fail |
Mechanical parts and assemblies
| Task | The agent must | Verified by |
|---|---|---|
| Drawing to model | Build the parametric part a drawing describes | The geometry verifier below |
| Apply a change order | Edit the part to a change request, regenerate it and re-quote it | The geometry verifier, and a recomputed quote |
| Read the drawing | Answer what only the drawing set can answer: counts, fits, cross-sheet references | Typed answer, compared field by field |
| Make it manufacturable | Flag what the plant cannot make or hold to tolerance, and propose the cheapest fix | Recomputation from the plant’s capability table |
Energy and utilities engineering
| Task | The agent must | Verified by |
|---|---|---|
| Bill of materials from the drawings | Take off modules, inverters, cable, pipe and valves from the layout, single-line diagram or P&ID | Recomputation from the drawings, with a tolerance per item |
| Single-line diagram check | Check string sizing, cable ratings and protection against the design rules | Rule recomputation; each clause pass or fail |
| Commissioning against design | Find where the commissioning records, the P&ID and the equipment list disagree | Set match against known discrepancies |
How verification works
We measure the feature, not the silhouette.
Three gates must pass first; fail one and the score is zero. Then each weighted check is scored on its own, so the score shows what broke.
Reads gate
The file exists and reads; a submitted script rebuilds on a clean kernel. A part that only looks finished stops here.
Valid solid gate
Closed and valid, one body where one is asked for.
Units and size gate
The stated units, inside the stated working volume.
Envelope and shape checks
Overall size, volume and overlap against the reference.
Features checks
Each toleranced bore, slot, wall and hole pattern, measured on the solid; faces checked for type.
Engineering checks
Mass, capacity, stability or the quote, recomputed where the task asks for them.
Which designs are excluded?
No naval or government vessels, and no third-party drawings without cleared rights. Engineering licensing requirements.
How is a set scoped?
We agree the domain, the access mode, the task families, the source, the volume and the splits in a written scope before any task is built.
Scope an engineering set with us.
Tell us the engineering capability and the file formats your agent uses. We agree the source material, deliverables and acceptance checks before building a pilot.